PME (MP modules...)

PME

The bus-connected and easy-to-use PME measuring system is suitable for industrial applications thanks to its intelligent modules.

The PME intelligent measuring system is ideal for use in decentralized measuring systems such as production processes in the engineering industry, as well as in test and test benches. PME modules record relevant measured quantities such as force, pressure, temperature, speed, moment of force and convert them into digital form. The "Assistant" software and standard interfaces for industrial buses such as CAN and Profibus DP allow the modules to be quickly integrated into industry.

 

PME system features:
  • High precision with 24-bit resolution
  • Up to 8 measuring channels
  • Inputs available for measurement of all common measurement quantities (e.g. strain gauges, inductance sensors, DC voltage, thermocouples, moments of force, speed/angle of rotation)
  • standard CAN interface
  • Optional PROFIBUS DP interface
  • Compact duralumin housing
  • EMC interference protection
  • Zener Barriers can be used for explosion hazardous environments
  • Optical control of limit switches, peak value memories, control inputs and outputs
  • Easy fault diagnosis
  • Manual or PC/PLC operation
  • Support software for parameterization and quick setup included
  • Possibility to save settings in parametric sets
  • Easy-to-read LCD display
  • Membrane keyboard
  • Wide range of accessories

 

MP55 and MP55DP measuring amplifier
  • Measuring amplifier for strain gauge full bridges. Accuracy class 0.1%, bridge power supply with carrier frequency 4.8kHz. Zeroing, tare, maximum and minimum signal detectors, 4 level comparators, adjustable low pass filter 0.05-500Hz, 4 binary inputs/outputs, voltage/current output, CANbus communication, 18-30VDC power supply. Alphanumeric LCD display, three control buttons, duralumin housing with DIN rail connection according to EN 50022, IP20 protection.
    Version MP55DP Profibus DP interface
Measuring amplifier - counter MP60 and MP60DP
  • Measuring amplifier for frequency measurement and reading from incremental sensors or torsion sensors. HBM. Accuracy class 0.05%. Zeroing, tare, maximum and minimum signal detectors, 4 level comparators, 4 binary inputs/outputs, voltage output, CANbus communication, 18-30VDC power supply. Alphanumeric LCD display, three control buttons, duralumin housing with DIN rail connection according to EN 50022, IP20 protection.
    Version MP60DP Profibus DP interface.

 

Measuring amplifier MP85A
  • Two-channel measuring amplifier for monitoring the dependence of two variables. Accuracy class 0.1%, two independent voltage inputs ±10V, incremental sensors, SSI sensors, strain gauge or inductance full bridges or half bridges (4.8kHz carrier frequency supply), potentiometers. Zeroing, tare, maximum and minimum signal detectors, 4 level comparators, adjustable low pass filter 0.05-1000Hz, 5 binary inputs, 8 binary outputs, CANbus communication, Ethernet, 18-30VDC power supply. Alphanumeric LCD display, three control buttons, duralumin housing with DIN rail connection according to EN 50022, IP20 protection.
Measuring amplifier MP85ADP
  • Two-channel measuring amplifier for monitoring the dependence of two variables. Accuracy class 0.1%, two independent voltage inputs ±10V, incremental sensors, SSI sensors, strain gauge or inductance full bridges or half bridges (4.8kHz carrier frequency supply), potentiometers. Zeroing, tare, maximum and minimum signal detectors, 4 level comparators, adjustable low pass filter 0.05-1000Hz, 1 binary input, 4 binary outputs, CANbus communication, Profibus DP interface, 18-30VDC power supply. Alphanumeric LCD display, three control buttons, duralumin housing with DIN rail connection according to EN 50022, IP20 protection.

 

Measuring module MP01 - No longer available. Possible replacement ClipX 1-BM40/1-BM40IE/1-BM40PB.
  • Measuring amplifier with four inputs for voltage, current and thermocouples or two inputs for Pt100. Accuracy class 0.1%. Zeroing, tare, maximum and minimum signal detectors, 4 level comparators, adjustable low pass filter 0.05-500Hz, 4 binary inputs/outputs, voltage output, CANbus communication, 18-30VDC power supply. Alphanumeric LCD display, three control buttons, duralumin housing with DIN rail connection according to EN 50022, IP20 protection.

 

MP30 and MP30DP measuring amplifier - No longer available. Possible replacement ClipX 1-BM40/1-BM40IE/1-BM40PB.
  • Measuring amplifier for strain gauge full bridges. Accuracy class 0.03%, bridge power supply with 600Hz carrier frequency. Zeroing, tare, maximum and minimum signal detectors, 4 level comparators, adjustable low pass filter 0.05-20Hz, 4 binary inputs/outputs, voltage output, CANbus communication, 18-30VDC power supply. Alphanumeric LCD display, three control buttons, duralumin housing with DIN rail connection according to EN 50022, IP20 protection.
    Version MP30DP Profibus DP interface.

 

Measuring amplifier MP55IBS - No longer available. 
  • Measuring amplifier for strain gauge solid bridges. Accuracy class 0.1%, bridge power supply with carrier frequency 4.8kHz. Zeroing, tare, maximum and minimum signal detectors, 4 level comparators, adjustable low pass filter 0.05-500Hz, 4 binary I/Os, voltage output, CANbus communication, Interbus S interface, 18-30VDC power supply. Alphanumeric LCD display, three control buttons, duralumin housing with DIN rail connection according to EN 50022, IP20 protection.

 

Special module MP70DP - No longer available. 
  • Gateway from Profibus DP to CANbus with up to eight modules (MP30, MP55, MP01, MP60) Arithmetic functions (addition, mean, multiplication of two channels, etc.), CANbus or manual setting, 18-30VDC power supply. Alphanumeric LCD display, three control buttons, duralumin housing with DIN rail connection according to EN 50022, IP20 protection.

 

Special module MP70DPS7 - No longer available. 
  • Gateway from Profibus DP to CANbus with up to eight modules (MP30, MP55, MP01, MP60) Arithmetic functions (addition, mean, multiplication of two channels, etc.), CANbus or manual setting, 18-30VDC power supply, four control inputs and four outputs, analogue output. Alphanumeric LCD display, three control buttons, duralumin housing with DIN rail connection according to EN 50022, IP20 protection.

 

 

 

I am interested in this product